DocumentCode
2555470
Title
Efficient optimization for adaptive SPECT systems based on local shift-invariance
Author
Pato, Lara R. V. ; Vandenberghe, Stefaan ; Van Holen, Roel
Author_Institution
Dept. of Electron. & Inf. Syst., Ghent Univ., Ghent, Belgium
fYear
2012
fDate
Oct. 27 2012-Nov. 3 2012
Firstpage
2501
Lastpage
2508
Abstract
Adaptive SPECT systems automatically change some of their settings to maximize the image quality for a given subject and purpose. This approach has a lot of potential, and could lead to drastic improvements in performance. In particular, it would be very useful in high resolution pinhole SPECT, where the low sensitivity requires higher radiation doses or longer imaging times compared to other systems. In order to have adaptation in real-time, we need a fast method for optimizing the adaptive settings according to a given figure of merit. This is still a big challenge. Based on previous work, we address in this paper the issue of fast evaluation of image quality and optimization, for a class of adaptive SPECT systems. We evaluate the image quality in a voxel of interest, reconstructed using postfiltered MLEM, with the contrast-to-noise ratio (CNR). The CNR is computed analytically, using an approximation based on the Fisher information matrix and assuming local shift-invariance on the Fisher information matrices per adaptation parameter. We maximize the CNR with a gradient based optimization approach. We then test this method in the optimization of the angular sampling of a single-head SPECT system which rotates around a phantom. In this case, the method proved to be very efficient, and at the same time showed good agreement with previous results in literature and with the outcome from reconstructions.
Keywords
dosimetry; image denoising; image reconstruction; medical image processing; optimisation; single photon emission computed tomography; Fisher information matrices; adaptive SPECT systems; angular sampling optimization; contrast-noise ratio; gradient based optimization approach; high radiation doses; high resolution pinhole SPECT; image quality; local shift-invariance; phantom; post-filtered MLEM reconstructions; single-head SPECT system; voxel of interest; Adaptive imaging; Fisher information matrix; evaluation of image quality; local shift-invariant approximation; optimization; pinhole SPECT; post-filtered MLEM reconstruction;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
Conference_Location
Anaheim, CA
ISSN
1082-3654
Print_ISBN
978-1-4673-2028-3
Type
conf
DOI
10.1109/NSSMIC.2012.6551571
Filename
6551571
Link To Document