Abstract :
In current computed tomography (CT) architecture, both X-ray tubes and X-ray detectors are rotated mechanically around an object to collect a sufficient number of projections. This architecture has been shown to not be fast enough for patients with high or irregular heart rates. Furthermore, both X-ray beams and detectors of the current architecture are made wide enough, so that the entire object is covered in the lateral direction without data truncation. Although novel acquisition protocols have recently been developed to reduce a radiation exposure, the high radiation dose from CT imaging remains a heightened public concern (especially for cardiac CT). The current CT architecture is a major bottleneck to further increase the temporal resolution and reduce the radiation dose. To overcome these problems, we present an innovative stationary-sources rotating-detectors CT (SSRD-CT) architecture based on the three stationary distributed X-ray sources and three smaller rotating X-ray detectors. Each distributed X-ray source has ~ 100 distinctive X-ray focal spots, and each detector has a narrower width compared with the conventional CT detectors. The SSRD-CT will have a field-of-view of 200 mm in diameter at isocenter, which is large enough to image many internal organs, including hearts. X-rays from the distributed sources are activated electronically to simulate the mechanical spinning of conventional single-beam X-ray sources with a high speed. The activation of individual X-ray beam will be synchronized to the corresponding rotating detector at the opposite end. Three source-detector chains can work in parallel to acquire three projections simultaneously and improve temporal resolution. Lower full-body radiation dose is expected for the proposed SSRD-CT because X-rays are restricted to irradiate a local smaller region. Taken together, the proposed SSRD-CT architecture will enable ≤50-ms temporal resolution and reduce radiation dose significantly.
Keywords :
X-ray tubes; biomedical equipment; cardiology; computerised tomography; dosimetry; image resolution; medical image processing; CT architecture; CT imaging; SSRD-CT architecture; X-ray beams; X-ray detectors; X-ray focal spots; X-ray tubes; computed tomography architecture; conventional CT detectors; conventional single-beam X-ray sources; current CT architecture; hearts; high radiation dose; high temporal resolution; low full-body radiation dose; low radiation dose; mechanical spinning; narrow width; small rotating X-ray detectors; source-detector chains; stationary distributed X-ray sources; stationary-source rotating-detectors; Biomedical imaging; Computed tomography; Computer architecture; Detectors; Electron tubes; Heart rate; Image resolution; Radiation monitoring; X-ray detectors; X-ray imaging; Computed tomography; computed tomography; interior tomography; multi-source; multisource; radiation dose; temporal resolution;
fLanguage :
English
Journal_Title :
Access, IEEE
Publisher :
ieee
ISSN :
2169-3536
Type :
jour
DOI :
10.1109/ACCESS.2014.2363367
Filename :
6928482
Link To Document :
بازگشت