DocumentCode
255601
Title
System design for junction temperatures up to 200°C
Author
Krone, T. ; Koneke, T. ; Mertens, Axel
Author_Institution
Inst. for Drive Syst. & Power Electron., Leibniz Univ. Hannover, Hannover, Germany
fYear
2014
fDate
26-28 Aug. 2014
Firstpage
1
Lastpage
10
Abstract
Manufacturers of power semiconductors and modules intend to rate the maximum junction temperature up to 200°C. This results in higher temperatures at other components of the inverter system as well. In this paper, it is presented a method to identify thermal constraints in an inverter design by combining analytical and numerical analysis of the thermal spreading. Furthermore, an overview of the thermal limits of the inverter´s components is given. The resulting thermal constraints of an air-cooled system are discussed, and it is introduced an inverter design to avoid over-temperatures. Finally, the test results achieved from the constructed inverter at 200°C junction temperature are presented.
Keywords
cooling; invertors; numerical analysis; power semiconductor devices; temperature measurement; thermal analysis; air-cooled system; analytical analysis; inverter design; inverter system; junction temperatures; numerical analysis; power modules; power semiconductors; temperature 200 degC; thermal constraints; thermal spreading; Copper; Heat sinks; Inverters; Junctions; Temperature measurement; Thermal conductivity; Thermal resistance; High temperature electronics; IGBT; Thermal design; Thermal stress;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics and Applications (EPE'14-ECCE Europe), 2014 16th European Conference on
Conference_Location
Lappeenranta
Type
conf
DOI
10.1109/EPE.2014.6910831
Filename
6910831