• DocumentCode
    255601
  • Title

    System design for junction temperatures up to 200°C

  • Author

    Krone, T. ; Koneke, T. ; Mertens, Axel

  • Author_Institution
    Inst. for Drive Syst. & Power Electron., Leibniz Univ. Hannover, Hannover, Germany
  • fYear
    2014
  • fDate
    26-28 Aug. 2014
  • Firstpage
    1
  • Lastpage
    10
  • Abstract
    Manufacturers of power semiconductors and modules intend to rate the maximum junction temperature up to 200°C. This results in higher temperatures at other components of the inverter system as well. In this paper, it is presented a method to identify thermal constraints in an inverter design by combining analytical and numerical analysis of the thermal spreading. Furthermore, an overview of the thermal limits of the inverter´s components is given. The resulting thermal constraints of an air-cooled system are discussed, and it is introduced an inverter design to avoid over-temperatures. Finally, the test results achieved from the constructed inverter at 200°C junction temperature are presented.
  • Keywords
    cooling; invertors; numerical analysis; power semiconductor devices; temperature measurement; thermal analysis; air-cooled system; analytical analysis; inverter design; inverter system; junction temperatures; numerical analysis; power modules; power semiconductors; temperature 200 degC; thermal constraints; thermal spreading; Copper; Heat sinks; Inverters; Junctions; Temperature measurement; Thermal conductivity; Thermal resistance; High temperature electronics; IGBT; Thermal design; Thermal stress;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Applications (EPE'14-ECCE Europe), 2014 16th European Conference on
  • Conference_Location
    Lappeenranta
  • Type

    conf

  • DOI
    10.1109/EPE.2014.6910831
  • Filename
    6910831