Title :
Effect of temperature rise and water contamination on leakage current in underwater used XLPE insulated power cables
Author :
Eish, Taher D. ; Youssef, Fathi M H ; El-Dessouky, S.S.
Author_Institution :
Dept. of Electr. Eng., Mansoura Univ., Egypt
fYear :
1988
fDate :
5-8 Jun 1988
Firstpage :
343
Lastpage :
346
Abstract :
Results of an experimental investigation into the effect of insulation temperature rise on the leakage current in crosslinked polyethylene (XLPE) insulated underwater power cables under alternating (50 Hz) and direct voltage stresses are presented. The effect of the surrounding water contamination and the size of XLPE cable as well as the applied voltage on leakage current are investigated. The results are compared with experimental results on impregnated-paper submarine cables of the same ratings. (1) Insulation capacitive impedance is the dominant factor affecting leakage current under AC voltage stress, while insulation resistance is the main impedance limiting leakage current under DC voltage. (2) The leakage current increases with applied AC and DC voltage. (3) Nonlinearity of leakage current vs. applied DC voltage can be caused by corona discharge currents. (4) The leakage current in XLPE cables increases with decreasing water resistivity and becomes higher than that of impregnated-paper submarine cables for water salt-content near that of natural seawater. (5) Insulation temperature has a great effect on the leakage current of XLPE cables, whereas leakage current of impregnated-power submarine cables does not change significantly with temperature due to their better thermal conductivity
Keywords :
cable insulation; insulation testing; leakage currents; organic insulating materials; polymers; power cables; submarine cables; 50 Hz; AC stress; DC stress; XLPE insulated power cables; capacitive impedance; corona discharge currents; impregnated-paper submarine cables; insulation resistance; leakage current; seawater; temperature rise; underwater power cables; water contamination; Cable insulation; Contamination; Impedance; Leakage current; Power cables; Stress; Temperature; Underwater cables; Voltage; Water pollution;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation, 1988., Conference Record of the 1988 IEEE International Symposium on
Conference_Location :
Cambridge, MA
ISSN :
1089-084X
Type :
conf
DOI :
10.1109/ELINSL.1988.13937
Filename :
13937
Link To Document :
بازگشت