• DocumentCode
    255895
  • Title

    Comparison of electric motor types for realising an energy efficient pumping system

  • Author

    Ahonen, Tapani ; Tamminen, Jussi ; Montonen, Juho

  • Author_Institution
    Lappeenranta Univ. of Technol., Lappeenranta, Finland
  • fYear
    2014
  • fDate
    26-28 Aug. 2014
  • Firstpage
    1
  • Lastpage
    9
  • Abstract
    Energy efficiency in pumping is partially affected by the electric motor efficiency. In addition to low losses, the chosen electric motor type should have feasible reliability and dimensions for pumping systems. This paper studies the applicability of common electric motor types to a future pumping system by comparing motor characteristics with each other; both a qualitative and quantitative evaluation is performed for a 15 kW induction, synchronous reluctance and permanent magnet synchronous motor. Another main object of this paper is to provide basic information for designing a next generation, more energy efficient pumping system.
  • Keywords
    induction motors; permanent magnet motors; power system reliability; pumps; reluctance motors; electric motor; energy efficient pumping system reliability; induction motor; permanent magnet synchronous reluctance motor; power 15 kW; Electric motors; Energy efficiency; Induction motors; Permanent magnet motors; Pumps; Reluctance motors; Electrical machine; Induction motor; Permanent magnet motor; Reluctance drive; System integration;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Applications (EPE'14-ECCE Europe), 2014 16th European Conference on
  • Conference_Location
    Lappeenranta
  • Type

    conf

  • DOI
    10.1109/EPE.2014.6910989
  • Filename
    6910989