Comparison of electric motor types for realising an energy efficient pumping system
Author
Ahonen, Tapani ; Tamminen, Jussi ; Montonen, Juho
Author_Institution
Lappeenranta Univ. of Technol., Lappeenranta, Finland
fYear
2014
fDate
26-28 Aug. 2014
Firstpage
1
Lastpage
9
Abstract
Energy efficiency in pumping is partially affected by the electric motor efficiency. In addition to low losses, the chosen electric motor type should have feasible reliability and dimensions for pumping systems. This paper studies the applicability of common electric motor types to a future pumping system by comparing motor characteristics with each other; both a qualitative and quantitative evaluation is performed for a 15 kW induction, synchronous reluctance and permanent magnet synchronous motor. Another main object of this paper is to provide basic information for designing a next generation, more energy efficient pumping system.
Keywords
induction motors; permanent magnet motors; power system reliability; pumps; reluctance motors; electric motor; energy efficient pumping system reliability; induction motor; permanent magnet synchronous reluctance motor; power 15 kW; Electric motors; Energy efficiency; Induction motors; Permanent magnet motors; Pumps; Reluctance motors; Electrical machine; Induction motor; Permanent magnet motor; Reluctance drive; System integration;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics and Applications (EPE'14-ECCE Europe), 2014 16th European Conference on
Conference_Location
Lappeenranta
Type
conf
DOI
10.1109/EPE.2014.6910989