Abstract
In this paper single-phase shunt active power filter (APF) for distributed power factor correction is presented. The APF is employed to correct the power factor of groups of loads, compensating for the load current harmonic distortion as well as for the fundamental load current displacement factor. The full-bridge voltage source inverter with a three level modulation technique is used as the APF. Theoretical analysis and experimental results of a 6 kVA APF compensating for a group of loads are provided
Keywords
active filters; bridge circuits; harmonic distortion; invertors; power factor correction; power harmonic filters; power system harmonics; 6 kVA; distributed power factor correction; full-bridge voltage source inverter; fundamental load current displacement factor; load current harmonic distortion compensation; single-phase active power filters; single-phase shunt active power filter; three level modulation technique; Active filters; Harmonic distortion; Interference; Inverters; Pollution; Power factor correction; Power harmonic filters; Power system harmonics; Reactive power; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics Specialists Conference, 2000. PESC 00. 2000 IEEE 31st Annual
Conference_Location
Galway
ISSN
0275-9306
Print_ISBN
0-7803-5692-6
Type
conf
DOI
10.1109/PESC.2000.878912
Filename
878912
Link To Document