DocumentCode :
2561163
Title :
Application of adaptive kinetic modeling for bias propagation reduction in direct 4D image reconstruction
Author :
Kotasidis, Fotis A. ; Matthews, Julian C. ; Reader, Andrew J. ; Angelis, Georgios I. ; Zaidi, Habib
Author_Institution :
Div. of Nucl. Med. & Mol. Imaging, Geneva Univ. Hosp., Geneva, Switzerland
fYear :
2012
fDate :
Oct. 27 2012-Nov. 3 2012
Firstpage :
3688
Lastpage :
3694
Abstract :
Direct 4D image reconstruction algorithms can improve kinetic parameter precision and accuracy in dynamic PET/CT body imaging but in contrast to post-reconstruction kinetic analysis, errors in badly modeled regions will spatially propagate to regions which are well modeled. To reduce error propagation from erroneous model fits, we propose a new approach to direct 4D image reconstruction by incorporating a newly proposed kinetic modeling strategy. This uses a secondary model to allow a less constrained model fit in regions where an erroneous kinetic model is used and adaptively include a portion of the residuals back into the image, whilst preserving the primary model characteristics in other well modeled regions. Using a digital 4-D phantom to simulate [15O]-H2O kinetics, we demonstrate substantial bias reduction due to propagation in all kinetic parameters using the proposed 4-D method. Under noisy conditions improvements in bias due to propagation are obtained at the expense of a small increase in bias due to noise and selective inclusion of residuals coming from erroneous kinetic modeling, as opposed to noise, becomes more challenging. However, the overall bias is reduced with improvements depending on the proximity of regions of interest to badly modeled regions and the choice of the secondary model space.
Keywords :
image denoising; image reconstruction; medical image processing; phantoms; positron emission tomography; adaptive kinetic modeling; bias propagation reduction; digital 4-D phantom; direct 4D image reconstruction algorithms; dynamic PET-CT body imaging; kinetic parameter; kinetic parameters; noisy conditions; post-reconstruction kinetic analysis; secondary model space; Direct 4-D image reconstruction; adaptive kinetic modeling; parametric imaging;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
Conference_Location :
Anaheim, CA
ISSN :
1082-3654
Print_ISBN :
978-1-4673-2028-3
Type :
conf
DOI :
10.1109/NSSMIC.2012.6551848
Filename :
6551848
Link To Document :
بازگشت