DocumentCode
256123
Title
Comparison between DTC using a two-level inverters and DTC using a three level inverters of induction motor
Author
Ouboubker, Lahcen ; Khafallah, M. ; Lamterkati, Jawad ; Chikh, Khalid
Author_Institution
Dept. of Electr. Eng., Hassan II Univ., Casablanca, Morocco
fYear
2014
fDate
14-16 April 2014
Firstpage
1051
Lastpage
1058
Abstract
This paper is to compare the DTC applied to an induction motor fed by two-level voltage inverters and a three level voltage inverters, and to demonstrate the great advantages of using a three-level inverters type NPC. The speed control is realised by using a PI controler. The effectiveness of this approach is shows by simulation results using Power System Blocset (PSB) of Matlab / Simulink.
Keywords
PI control; induction motors; invertors; machine control; torque control; velocity control; DTC; Matlab; PI controler; PSB; Power System Blocset; Simulink; direct torque control; induction motor; speed control; three level voltage inverters; two-level voltage inverters; Hysteresis motors; Induction motors; Inverters; Stators; Torque; Vectors; Voltage control; DTC; induction motor; three levels invertesr corrector PI; two level inverter;
fLanguage
English
Publisher
ieee
Conference_Titel
Multimedia Computing and Systems (ICMCS), 2014 International Conference on
Conference_Location
Marrakech
Print_ISBN
978-1-4799-3823-0
Type
conf
DOI
10.1109/ICMCS.2014.6911167
Filename
6911167
Link To Document