  • Abstract
    Three changes that were introduced to automate totally a voltage standard system based on a 10-V Josephson array are described. A commercial standard cell scanner controls switching for calibrating either Zener references or digital voltmeters, a programmable attenuator helps in obtaining voltage steps, and measurements of digital voltmeter noise help in verifying array stability. The array system operates completely unattended.<>
  • Keywords
    Josephson effect; Zener diodes; calibration; digital voltmeters; superconducting junction devices; voltage measurement; 10 V; 10-V Josephson array; Zener references; automation; calibration; digital voltmeters; noise; programmable attenuator; programmable mm-wave attenuator; stability; standard cell scanner; voltage standard; voltage steps; Calibration; Circuits; Measurement standards; NIST; Noise level; Noise measurement; Switches; Voltage; Voltmeters; Wiring;