  • Abstract
    The Danish system for calibration of DC voltages up to 10 V is described. Emphasis is on the design and verification of the Josephson array setup and the certified scheme based on Zener references for dissemination of traceability to industry. To correct for offset and linear drift, three null measurements and two array voltage reversals are used in the calibration procedure. The uncorrected thermal voltages and drift originating mainly from the switch box are estimated to be about 1 nV. Calibration of the 10-V terminals is done by means of a high-linearity voltmeter. The nonlinearity of the voltmeter is the major source of error in the method.<>
  • Keywords
    Josephson effect; calibration; measurement errors; measurement standards; superconducting junction devices; voltage measurement; 10 V; DC voltages; Danish Josephson array; array voltage reversals; error; linear drift; nonlinearity; null measurements; offset; thermal voltages; traceability; voltage calibration; voltmeter; Calibration; Design for manufacture; Frequency conversion; Josephson junctions; Metrology; Microwave oscillators; NIST; Stability; Voltage; Voltage-controlled oscillators;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 1990. CPEM '90 Digest., Conference on
  • Conference_Location
    Ottawa, Ontario, Canada
  • Type

    conf

  • DOI
    10.1109/CPEM.1990.109949
  • Filename
    109949