DocumentCode
2561671
Title
Multiplexing strategies for cMiCE PET detectors
Author
Miyaoka, Robert S. ; Hunter, William C. J. ; Pierce, Leland
Author_Institution
Dept. of Radiol., Univ. of Washington, Seattle, WA, USA
fYear
2012
fDate
Oct. 27 2012-Nov. 3 2012
Firstpage
3821
Lastpage
3824
Abstract
Continuous miniature crystal element (cMiCE) PET detectors use monolithic scintillators coupled to arrays of photosensor elements and statistics based methods for positioning of detected events. Current implementations acquire and utilize all photosensor array channels for event positioning (e.g., 64 channels for an 8×8 PMT or SiPM array). We investigate different multiplexing strategies to reduce the number of acquired signal channels and their impact on positioning performance. This study was conducted using data collected from a cMiCE PET detector. Sixty-four signals were collected per event and data were binned into four depth of interaction regions. The multiplexing strategies were implemented in software. Multiplexing strategies investigated included rowcolumn (RC) summing of signals (64 channel -> 16 channel); sampling based upon a modulus 3 and modulus 5 patterns of detector channels (64 -> 16); variants of RC summing (e.g., 64 -> 19 or 64 -> 8); and multiplexing based upon principal component analysis. The average X,Y intrinsic spatial resolution for the cMiCE detector using all 64 channels for positioning was 1.26 mm FWHM in X and Y. For standard RC summing of signals the average intrinsic X,Y spatial resolution was 1.32 mm. The intrinsic spatial resolution for the modulus 3 and 5 multiplexing was significantly worse at 1.43 mm FWHM. A RC summing method that used three additional multiplexed channels along the edges of the crystal provided similar decoding performance as standard RC summing (i.e., 1.31 mm) but better visual spatial positioning in the corners and edges of the detector. However, the most encouraging results were using multiplexing methods based upon the principal components of the detector signals; the intrinsic spatial resolution for this method was best of all the multiplexing methods (i.e., 1.30 mm FWHM) and it proved to be fairly robust to slight changes in the weighting factors. In conclusion, signal multiplexin- techniques can be applied to monolithic crystal PET detectors that utilize statistics-based positioning methods. Reductions in the number of acquisition signal channels of a factor of 3-5 resulted in only 4-10% degradation in spatial resolution performance.
Keywords
decoding; multiplexing; optical sensors; position sensitive particle detectors; positron emission tomography; principal component analysis; solid scintillation detectors; RC summing method; cMiCE PET detectors; continuous miniature crystal element; decoding; depth-of-interaction regions; event positioning; modulus; monolithic scintillators; multiplexing; photosensor array channels; principal component analysis; spatial resolution; statistics-based positioning; weighting factors;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
Conference_Location
Anaheim, CA
ISSN
1082-3654
Print_ISBN
978-1-4673-2028-3
Type
conf
DOI
10.1109/NSSMIC.2012.6551877
Filename
6551877
Link To Document