• DocumentCode
    2562111
  • Title

    Determination of the volt with the improved PTB voltage balance

  • Author

    Funck, T. ; Sienknecht, V.

  • Author_Institution
    Phys.-Tech. Bundesanstalt, Braunschweig, Germany
  • fYear
    1990
  • fDate
    11-14 June 1990
  • Firstpage
    182
  • Abstract
    Determinations of the conversion factor of the volt have been carried out after significant improvements to the measuring system. The mean value of 48 determinations was K/sub V/=1-0.02*10/sup -6/, with a standard deviation of the mean s/sub m/=0.064*10/sup -6/. The corresponding frequency-to-voltage quotient is K/sub J/=483597.91 GHz/V. The relative type B uncertainty of the experiment was estimated to be u=0.33*10/sup -6/. These data are preliminary, in as much as the recalibration of the standards used for the capacitance, the mass, and the displacement in terms of the SI units farad, kilogram, and meters had not yet been carried out.<>
  • Keywords
    units (measurement); voltage measurement; PTB voltage balance; conversion factor; frequency-to-voltage quotient; measurement standard; standard deviation; volt; Capacitance measurement; Capacitive sensors; Displacement measurement; Electrodes; Electrostatic measurements; Force measurement; Frequency measurement; Measurement standards; Optical sensors; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 1990. CPEM '90 Digest., Conference on
  • Conference_Location
    Ottawa, Ontario, Canada
  • Type

    conf

  • DOI
    10.1109/CPEM.1990.109980
  • Filename
    109980