DocumentCode :
2562111
Title :
Determination of the volt with the improved PTB voltage balance
Author :
Funck, T. ; Sienknecht, V.
Author_Institution :
Phys.-Tech. Bundesanstalt, Braunschweig, Germany
fYear :
1990
fDate :
11-14 June 1990
Firstpage :
182
Abstract :
Determinations of the conversion factor of the volt have been carried out after significant improvements to the measuring system. The mean value of 48 determinations was K/sub V/=1-0.02*10/sup -6/, with a standard deviation of the mean s/sub m/=0.064*10/sup -6/. The corresponding frequency-to-voltage quotient is K/sub J/=483597.91 GHz/V. The relative type B uncertainty of the experiment was estimated to be u=0.33*10/sup -6/. These data are preliminary, in as much as the recalibration of the standards used for the capacitance, the mass, and the displacement in terms of the SI units farad, kilogram, and meters had not yet been carried out.<>
Keywords :
units (measurement); voltage measurement; PTB voltage balance; conversion factor; frequency-to-voltage quotient; measurement standard; standard deviation; volt; Capacitance measurement; Capacitive sensors; Displacement measurement; Electrodes; Electrostatic measurements; Force measurement; Frequency measurement; Measurement standards; Optical sensors; Voltage measurement;