• DocumentCode
    2562670
  • Title

    Fabricating high-resolution and high-sensitivity scintillator arrays using Laser Induced Optical Barriers

  • Author

    Sabet, Hamid ; Kudrolli, Haris ; Singh, Bawa ; Nagarkar, Vivek V.

  • Author_Institution
    Radiat. Monitoring Devices, Inc., Watertown, MA, USA
  • fYear
    2012
  • fDate
    Oct. 27 2012-Nov. 3 2012
  • Firstpage
    4080
  • Lastpage
    4084
  • Abstract
    High-resolution positron emission tomography (PET) requires pixelated scintillators-however, if the pixelation process leaves inter-pixel gaps, the loss of material results in loss of sensitivity. PET sensitivity also requires scintillators such as LSO and L YSO to be thicker than 2 cm, due to the high penetrating power of 511 keV gamma rays. Fine pixelation of L YSO is difficult, since it is very hard material and is known to crack under thermal and mechanical stress. We have developed a method to introduce optical barriers within monolithic L YSO crystals to form pix elated arrays with small pixel size and large thickness. Arrays were fabricated using a high-frequency solid-state laser to form optical barriers (interpixel gaps), which can be as thin as 13 μm without affecting the transparency of the crystals. Our method yields near-perfect, extremely high aspect ratio pixels. By controlling parameters such as laser pulse repetition rate and energy density, LYSO crystals can be effectively pixelated with virtually no material loss. We have laser processed L YSO crystals ranging from 5 to 20 mm thick and 0.8×0.8 to 1.5×1.5 mm2 in pixel cross section. When a collimated beam (0.5 mm) of 70 kVp X-rays was incident on one pixel of a 10×10×20 mm3 scintillator array with 0.8×0.8 mm2 pixel size, an average optical crosstalk ratio was measured at 6.5:1, which shows excellent pixel separation. Our technique is ideal for fabricating scintillator arrays for clinical/pre-clinical PET and SPECT systems as well as photon counting CT detectors. Our technique is automated, and is cost-effective.
  • Keywords
    positron emission tomography; solid scintillation detectors; PET sensitivity; average optical crosstalk ratio; energy density; extremely high aspect ratio pixels; high penetrating power; high-frequency solid-state laser; high-resolution PET; high-sensitivity scintillator arrays; inter-pixel gaps; laser induced optical barriers; laser pulse repetition rate; mechanical stress; monolithic LYSO crystals; optical barriers; pixel size; pixelated arrays; pixelated scintillators; pixelation process; positron emission tomography; scintillator array; thermal stress; Cost-Effective; High-Resolution; LYSO;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    1082-3654
  • Print_ISBN
    978-1-4673-2028-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2012.6551932
  • Filename
    6551932