DocumentCode
2562949
Title
Experimental investigations on operation capacity of triggered vacuum switches
Author
Jiyan, Zou ; Xiongying, Duan ; Shihong, Qin
Author_Institution
Dalian Univ. of Technol., China
Volume
2
fYear
2000
fDate
2000
Firstpage
504
Abstract
The triggered vacuum switch (TVS) is the most successful controlling switch in the field of pulse power. We introduced the axial magnetic arc-controlling technique from the vacuum interrupters applied in a power system, that greatly improves TVS´ characteristics. In the paper, we made a series of experiments on the sample TVSs with high current LC loop, and obtained their breaking limitation under different loop frequency, which corresponds to different current decline rates and different arcing times. Experimental setup and results were introduced. Analysis shows that the current decline rate dominates breaking current limitation of TVSs. Arcing time affects breaking to some extent. We can expect TVS operation under the conditions of 10 kA/10 kHz. Because of the positive VI characteristic of vacuum arcs, TVSs can be used for higher current operations in parallel with synchronous triggering
Keywords
pulsed power switches; vacuum arcs; vacuum switches; 10 kA; 10 kHz; arcing times; axial magnetic arc-controlling technique; breaking limitation; current decline rates; high current LC loop; loop frequency; operation capacity; positive VI characteristic; synchronous triggering; triggered vacuum switches; vacuum arcs; vacuum interrupters; Costs; Electrodes; Frequency locked loops; Interrupters; Pulse power systems; Switches; Vacuum arcs; Vacuum systems; Vacuum technology; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Discharges and Electrical Insulation in Vacuum, 2000. Proceedings. ISDEIV. XIXth International Symposium on
Conference_Location
Xi´an
Print_ISBN
0-7803-5791-4
Type
conf
DOI
10.1109/DEIV.2000.879037
Filename
879037
Link To Document