• DocumentCode
    2562992
  • Title

    RF-DC differences of thermal voltage converters arising from input connectors (voltage measurement)

  • Author

    Huang, D.X. ; Kinard, J.R. ; Rebuldela, G.

  • Author_Institution
    Nat. Inst. of Stand. & Technol., Gaithersburg, MD, USA
  • fYear
    1990
  • fDate
    11-14 June 1990
  • Firstpage
    280
  • Lastpage
    281
  • Abstract
    The RF-DC differences of thermal voltage converters (TVCs) caused by the skin effect and transmission line effects of input structures of different length have been previously studied. Discrepancies have been found to exist between simple mathematical models and measured results for commonly used input connectors. A study of these discrepancies is reported. In particular, the change in RF-DC difference for a 0.5-V TVC resulting from the insertion of a 10-cm air line is evaluated.<>
  • Keywords
    convertors; skin effect; transmission lines; voltage measurement; 0.5 V; 10 cm; AC/DC conversion; RF-DC differences; air line; input connectors; mathematical models; skin effect; thermal voltage converters; transmission line effects; voltage measurement; Calibration; Connectors; Impedance; NIST; Power transmission lines; Radio frequency; Skin effect; Transmission line measurements; Transmission lines; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 1990. CPEM '90 Digest., Conference on
  • Conference_Location
    Ottawa, Ontario, Canada
  • Type

    conf

  • DOI
    10.1109/CPEM.1990.110023
  • Filename
    110023