Abstract
The RF-DC differences of thermal voltage converters (TVCs) caused by the skin effect and transmission line effects of input structures of different length have been previously studied. Discrepancies have been found to exist between simple mathematical models and measured results for commonly used input connectors. A study of these discrepancies is reported. In particular, the change in RF-DC difference for a 0.5-V TVC resulting from the insertion of a 10-cm air line is evaluated.<>
Keywords
convertors; skin effect; transmission lines; voltage measurement; 0.5 V; 10 cm; AC/DC conversion; RF-DC differences; air line; input connectors; mathematical models; skin effect; thermal voltage converters; transmission line effects; voltage measurement; Calibration; Connectors; Impedance; NIST; Power transmission lines; Radio frequency; Skin effect; Transmission line measurements; Transmission lines; Voltage measurement;