DocumentCode
2564426
Title
Acoustic monitoring of insulation delaminations during thermal cycling tests on a stator bar
Author
Zhu, H. ; Kung, D.
Author_Institution
Powertech Labs., Vancouver, BC, Canada
fYear
2009
fDate
May 31 2009-June 3 2009
Firstpage
183
Lastpage
187
Abstract
This paper describes a novel acoustic monitoring technique of insulation delaminations during a thermal cycling test (TC) on a stator bar. Acoustic signals emitted from insulation delaminations within the stator bar were continuously recorded during a TC test. An increase in measured acoustic signals indicates insulation delaminations within the stator bar under test. Dissipation factor tests, partial discharge tests, tap tests, and dissections were performed. Those diagnostic test results were compared with the acoustic test data to verify insulation delaminations. The acoustic monitoring system can indicate which cycle insulation delaminations occurred and when they occurred in a given thermal cycle during a TC test.
Keywords
acoustic signal detection; delamination; insulation testing; machine windings; stators; thermal stresses; acoustic monitoring; acoustic signals; dissections; dissipation factor tests; insulation delaminations; partial discharge tests; stator bar; tap tests; thermal cycling tests; Acoustic emission; Acoustic measurements; Acoustic testing; Delamination; Insulation testing; Monitoring; Partial discharge measurement; Partial discharges; Performance evaluation; Stators;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation Conference, 2009. EIC 2009. IEEE
Conference_Location
Montreal, QC
Print_ISBN
978-1-4244-3915-7
Electronic_ISBN
978-1-4244-3917-1
Type
conf
DOI
10.1109/EIC.2009.5166341
Filename
5166341