• DocumentCode
    2564979
  • Title

    Forensic analysis of a silicone oil filled mobile transformer

  • Author

    Penrose, Howard W.

  • Author_Institution
    SUCCESS by DESIGN®, Naperville, Illinois USA
  • fYear
    2009
  • fDate
    May 31 2009-June 3 2009
  • Firstpage
    359
  • Lastpage
    362
  • Abstract
    When a number of new silicone oil filled mobile transformers failed, an evaluation of one of the remaining transformers was commissioned. The forensic analysis involved the tear-down and evaluation of the working transformer and components. In this paper we will discuss the steps involved in developing this type of forensic analysis, a few of the findings, and recommendations. Problems identified a range from design issues through to insulation coordination issues that did not cause the initial failures, but were identified as high risk future issues.
  • Keywords
    power transformer insulation; transformer oil; forensic analysis; insulation coordination; oil analysis; silicone oil filled mobile transformer; transformer failure; Dielectrics and electrical insulation; Failure analysis; Forensics; Humans; Insulation life; Oil insulation; Petroleum; Pollution measurement; Power transformer insulation; USA Councils;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation Conference, 2009. EIC 2009. IEEE
  • Conference_Location
    Montreal, QC
  • Print_ISBN
    978-1-4244-3915-7
  • Electronic_ISBN
    978-1-4244-3917-1
  • Type

    conf

  • DOI
    10.1109/EIC.2009.5166370
  • Filename
    5166370