• DocumentCode
    2565300
  • Title

    Field experience in insulation diagnosis of industrial high voltage motors using dielectric response technique

  • Author

    Bhumiwat, S.A.

  • Author_Institution
    Independent High Voltage Diagnostics Consultant, P.O. Box 18-062 Glen Innes, Auckland 1743, New Zealand
  • fYear
    2009
  • fDate
    May 31 2009-June 3 2009
  • Firstpage
    454
  • Lastpage
    457
  • Abstract
    This article introduces the on-site non-destructive dielectric response technique as a diagnosis tool for in-service high voltage motors. It emphasizes the importance of depolarization current which shall be measured in conjunction with polarization current in order to identify the type of insulation trouble, while the time-domain together with the frequency-domain results give decisive information how healthy the insulation is for continued operation.
  • Keywords
    electric motors; frequency-domain analysis; insulation testing; machine insulation; nondestructive testing; time-domain analysis; dielectric response technique; industrial high voltage motors; insulation diagnosis; on-site non-destructive dielectric response; polarization current; Current measurement; Dielectric measurements; Dielectrics and electrical insulation; Frequency measurement; Insulation testing; Optical polarization; Rotating machines; Stators; Time domain analysis; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation Conference, 2009. EIC 2009. IEEE
  • Conference_Location
    Montreal, QC
  • Print_ISBN
    978-1-4244-3915-7
  • Electronic_ISBN
    978-1-4244-3917-1
  • Type

    conf

  • DOI
    10.1109/EIC.2009.5166389
  • Filename
    5166389