Real-time monitor for hemodynamic beat-to-beat parameters and power spectra analysis of the biosignals
Author
Fortin, J. ; Habenbacher, W. ; Gruellenberger, R. ; Wach, P. ; Skrabal, F.
Author_Institution
Inst. for Biomed. Eng., Graz Univ. of Technol., Austria
fYear
1998
fDate
29 Oct-1 Nov 1998
Firstpage
360
Abstract
In this work a system for the online analysis of all relevant hemodynamic parameters is introduced. The parameters are heart rate, systolic, diastolic and mean blood pressure, stroke volume, cardiac output, total peripheral resistance, inotropic state, oxygen saturation, several time intervals, the power of the high and low frequency band of hemodynamic time series and baroreceptor reflex sensitivity. The system consists of a patient biosignal electronic system (PBES) which is a self calibrating, non-invasive instrument for ECG, impedance cardiography ICG, continuous blood pressure and pulse oximetry. The data acquisition (DAQ) system is a personal computer with a C-based software for DAQ and virtual instrumentation. This software is controlling the calibration routines of the PBES, detecting the beat-to-beat hemodynamic parameters, computing the sliding power spectra and calculating the baroreceptor sensitivity. The data are visualised in real-time on the screen and finally an automatic report of the investigation is printed. A new algorithm for online QRS-detection and a new rejection method for the RLS-algorithm are included
Keywords
biomedical electronics; blood pressure measurement; cardiovascular system; computerised monitoring; data acquisition; electrocardiography; medical signal processing; oximetry; patient monitoring; spectral analysis; time series; virtual instrumentation; C-based software; ECG; RLS-algorithm; automatic report; baroreceptor reflex sensitivity; biosignal electronic system; calibration routines; cardiac output; continuous blood pressure; data acquisition system; diastolic pressure; heart rate; hemodynamic beat-to-beat parameters; hemodynamic time series; high frequency band; impedance cardiography; inotropic state; low frequency band; mean blood pressure; on-line QRS-detection algorithm; on-line analysis system; oxygen saturation; power spectra analysis; pulse oximetry; real-time monitor; rejection method; self calibrating noninvasive instrument; sliding power spectra; stroke volume; systolic pressure; time intervals; total peripheral resistance; virtual instrumentation; Baroreflex; Biomedical monitoring; Blood pressure; Condition monitoring; Data acquisition; Frequency; Heart rate; Hemodynamics; Immune system; Instruments;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 1998. Proceedings of the 20th Annual International Conference of the IEEE
Conference_Location
Hong Kong
ISSN
1094-687X
Print_ISBN
0-7803-5164-9
Type
conf
DOI
10.1109/IEMBS.1998.745917
Filename
745917
Link To Document