• DocumentCode
    2568269
  • Title

    Improved Readout Screens for Gated X-Ray Intensifiers

  • Author

    Bell, Perry M. ; Landen, O.L. ; Alvarez, S.S. ; Robinson, R.B. ; Charest, M.R. ; Stein, R.A. ; Walsh, Patrick J.

  • Author_Institution
    Lawrence Livermore Nat. Lab., CA
  • fYear
    2005
  • fDate
    20-23 June 2005
  • Firstpage
    158
  • Lastpage
    158
  • Abstract
    Summary form only given. High-energy-density-physics and inertial confinement fusion experiments done on Z pinch machines and laser facilities often use gated X-ray intensifiers (GXI) as the primary diagnostic. Improvements in resolution and background noise can be achieved with improved phosphor screens. We have developed several new sources for readout screens. Data will be presented that show resolution limits, signal to noise and luminosity at wavelengths useful for large area CCD readouts
  • Keywords
    Z pinch; plasma diagnostics; plasma inertial confinement; CCD; Z pinch; gated X-ray intensifiers; high energy density physics; inertial confinement fusion; laser facilities; luminosity; phosphor screens; Crystals; Detectors; Energy resolution; Laboratories; Plasma confinement; Plasma diagnostics; Plasma measurements; Plasma sources; Plasma x-ray sources; Spectroscopy;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Plasma Science, 2005. ICOPS '05. IEEE Conference Record - Abstracts. IEEE International Conference on
  • Conference_Location
    Monterey, CA
  • ISSN
    0730-9244
  • Print_ISBN
    0-7803-9300-7
  • Type

    conf

  • DOI
    10.1109/PLASMA.2005.359157
  • Filename
    4198416