DocumentCode :
2570542
Title :
Time and Space Resolved Multi View X-Ray Spectroscopy at Z using Elliptical Crystal Spectrometers
Author :
Lake, Patrick W. ; Bailey, J.E. ; Nielsen, David ; Gard, P. ; Petmecky, D. ; Bump, M. ; Calhoun, David ; Joseph, Naiji ; Moore, T.C.
Author_Institution :
Sandia Nat. Labs., Albuquerque, NM
fYear :
2005
fDate :
20-23 June 2005
Firstpage :
236
Lastpage :
236
Abstract :
Summary form only given. X-ray spectrometers used in modern high energy density (HED) plasma experiments must provide high time, space, and spectral resolution while overcoming the difficulties imposed by the environment, including x-ray background, debris, and mechanical shocks. At the Z facility these problems are addressed using a suite of elliptical crystal spectrometers. The elliptical geometry isolates the detector from the line of sight with a slit placed at the elliptical focus, while the sensitivity enables locating the crystal 2-4 meters from the plasma source. Space and time resolution are obtained by using an array of slits to project a ID plasma image onto the crystal and recording the spectrally-dispersed image with a gated MCP detector. A spectrometer equipped with two crystals is used to double the number of time frames, enabling longer time durations to be spanned by a single instrument. Alternatively, the double crystal design allows simultaneous measurements with different crystals to investigate different spectral regimes. A spectrometer observing the plasma from a given direction suffers from a problem common to many HED plasma diagnostics: the data are integrated along the instrument line of sight, possibly leading to complications if the emitting plasma is non-uniform. This problem is being addressed at Z by deploying three separate spectrometers that observe the plasma from three almost-orthogonal directions. Multi-view measurements are common in relatively-large magnetic fusion plasmas, but have not been previously acquired in HED plasmas because of the need for simultaneous high spatial and temporal resolution. Spectra acquired from multiple views can provide information about the plasma symmetry from diverse experiments, including inertial confinement fusion capsule implosions and Z-pinch plasmas.
Keywords :
Z pinch; explosions; plasma diagnostics; plasma inertial confinement; MCP detector; X-ray spectroscopy; Z facility; Z-pinch plasmas; capsule implosions; elliptical crystal spectrometers; high energy density plasma; inertial confinement fusion; magnetic fusion plasmas; mechanical shocks; plasma diagnostics; plasma source; plasma symmetry; Crystals; Detectors; Energy resolution; Instruments; Plasma confinement; Plasma density; Plasma diagnostics; Plasma measurements; Plasma sources; Spectroscopy;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Plasma Science, 2005. ICOPS '05. IEEE Conference Record - Abstracts. IEEE International Conference on
Conference_Location :
Monterey, CA
ISSN :
0730-9244
Print_ISBN :
0-7803-9300-7
Type :
conf
DOI :
10.1109/PLASMA.2005.359300
Filename :
4198559
Link To Document :
بازگشت