Design and testing of a heat pipe cooled thermionic energy convertor
Author
Veltkamp, W.B. ; Wolff, L.R. ; Schoonen, J.M.W.M. ; Bakker, R. ; Houtermans, M.P.A. ; de Pijper, A.M.
Author_Institution
Dept. of Mech. Eng., Eindhoven Univ. of Technol., Netherlands
fYear
1989
fDate
6-11 Aug 1989
Firstpage
1171
Abstract
Research on thermionic conversion (TEC) at the Eindhoven University of Technology is described. The initial fundamental research on emitter materials has been followed by the design, construction and testing of a flame-heated, air-cooled TEC. Air cooling of the collector with a sodium heat pipe has been preferred as it improves the thermodynamical behavior of the TEC in its prime application area, the electrical generator of a total energy module (TOTEM). Some results of the characterization of the materials used in the convertor, some design considerations for the air-cooled test TEC constructed recently, and test results for a sodium heat pipe collector are discussed
Keywords
heat pipes; testing; thermionic conversion; Eindhoven University of Technology; TOTEM; air-cooled test TEC; heat pipe cooled thermionic energy convertor; thermodynamical behavior; total energy module; Chemical technology; Cogeneration; Converters; Cooling; Electrodes; Energy conversion; Fires; Materials testing; Mechanical engineering; Plasma temperature;