DocumentCode :
2578489
Title :
Power System Blackouts - Minimizing Their Impact at Industrial Co-Generation Facilities
Author :
Mozina, Charles J.
Author_Institution :
Consultant-Beckwith Electr., Largo, FL
fYear :
2006
fDate :
11-15 Sept. 2006
Firstpage :
1
Lastpage :
8
Abstract :
Investigations of recent blackouts indicate that the root cause of almost all major power system disturbances is voltage collapse rather than the underfrequency conditions prevalent in the blackouts of the 1960s and 70s. This paper explores the nature of recent power system blackouts (2003 east coast, 1996 California and others) and explains why voltage is the leading edge indicator of impending power system collapse. The paper discusses the need to use voltage - as well as frequency - to decide when to separate from the utility system and transfer industrial system load to internal plant co-generation. Voltage relays have been used by industrial customers to determine that the utility circuit that supplies them has tripped. However, voltage relays at industrial sites have generally not been used to determine that the utility system lacks security and may collapse. This paper discusses the causes of voltage collapse as well as the design and security requirements for an undervoltage separation scheme. The paper addresses the current level of voltage load shedding on utilities´ systems, NERC (North Electric Reliability Council) requirements and coordination of industrial undervoltage separation with utility undervoltage load shedding
Keywords :
cogeneration; industrial plants; industrial power systems; power system dynamic stability; power system faults; power system reliability; security; industrial cogeneration facilities; power system blackouts; power system disturbance; security requirement; undervoltage separation; utility system; voltage collapse; Frequency; Industrial power systems; Power generation; Power system relaying; Power system reliability; Power transmission lines; Propagation losses; Reactive power; Security; Voltage; AVR; NERC; UFLS; UVLS; blackouts; frequency collapse; special protection schemes; voltage collapse;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Petroleum and Chemical Industry Conference, 2006. PCIC '06. Record of Conference Papers - IEEE Industry Applications Society 53rd Annual
Conference_Location :
Philadelphia, PA
ISSN :
0090-3507
Print_ISBN :
1-4244-0558-0
Electronic_ISBN :
0090-3507
Type :
conf
DOI :
10.1109/PCICON.2006.359685
Filename :
4199045
Link To Document :
بازگشت