DocumentCode
2578867
Title
Efficiency of active Double-Clad fiber pumping in different types of fibers
Author
Filip, P. ; Grobelny, A. ; Witkowski, J.S.
Author_Institution
Inst. of Telecommun., Wroclaw Univ. of Technol., Wroclaw
Volume
4
fYear
2008
fDate
22-26 June 2008
Firstpage
353
Lastpage
356
Abstract
In the paper the pumping efficiency of active, different types double-clad fiber has been analyzed. The ray tracing method has been applied for fibers analysis. The most often utilized fibers: circular non-concentric, D-shape, fin-shape, rectangular fibers have been analyzed. The results show that the geometry of the inner clad fibers is not very significant for pumping efficiency, except the case of circular one.
Keywords
fibre lasers; optical fibre cladding; optical pumping; ray tracing; D-shape fibers; active double-clad fiber pumping; circular nonconcentric fibers; fin-shape fibers; pumping efficiency; ray tracing method; rectangular fibers; Absorption; Acoustics; Apertures; Geometrical optics; Geometry; Optical fibers; Paper technology; Postal services; Ray tracing; Refractive index; double clad fiber; optical fiber system; pumping efficiency;
fLanguage
English
Publisher
ieee
Conference_Titel
Transparent Optical Networks, 2008. ICTON 2008. 10th Anniversary International Conference on
Conference_Location
Athens
Print_ISBN
978-1-4244-2625-6
Electronic_ISBN
978-1-4244-2626-3
Type
conf
DOI
10.1109/ICTON.2008.4598810
Filename
4598810
Link To Document