• DocumentCode
    2578997
  • Title

    Earth-fault protection of VLT® automationdrive FC 301

  • Author

    Andersen, Henrik Rosendal

  • Author_Institution
    DANFOSS DRIVES A/S, Graasten
  • fYear
    2007
  • fDate
    2-5 Sept. 2007
  • Firstpage
    1
  • Lastpage
    9
  • Abstract
    The earth-fault protection of VLTreg AutomationDrive FC 301 is based on a single current transducer in the high-side DC-link and desaturation protection of the low-side switching elements. Used together with a novel software algorithm this makes the AC-drive earth-fault proof in any operating point.
  • Keywords
    DC motor drives; earthing; power system faults; transducers; AutomationDrive FC 301; Earth-fault protection; VLT; desaturation protection; high-side DC-link; low-side switching elements; single current transducer; software algorithm; Circuit faults; Diodes; Earth; Protection; Rectifiers; Software algorithms; Solids; Stress; Transducers; Uniform resource locators; AC-drive; DC-link current sensing; PWM; desaturation protection; earth-fault protection;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Applications, 2007 European Conference on
  • Conference_Location
    Aalborg
  • Print_ISBN
    978-92-75815-10-8
  • Electronic_ISBN
    978-92-75815-10-8
  • Type

    conf

  • DOI
    10.1109/EPE.2007.4417238
  • Filename
    4417238