• DocumentCode
    2579138
  • Title

    Fabrication of nickel electroplated cantilever-type MEMS probe card with through-hole interconnection

  • Author

    Bong-Hwan Kim ; Sang-Jun Park ; Dong-Il Cho ; Kukjin Chun

  • Author_Institution
    Sch. of Electr. Eng., Seoul Nat. Univ., South Korea
  • fYear
    2003
  • fDate
    29-31 Oct. 2003
  • Firstpage
    170
  • Lastpage
    171
  • Abstract
    In this paper, a new cantilever type MEMS probe card for IC testing was developed. The probe was fabricated with silicon substrate.
  • Keywords
    contact resistance; electroplating; integrated circuit testing; leakage currents; micromechanical devices; nickel; probes; IC testing; Ni; Si; hole interconnection; nickel electroplated cantilever-type MEMS probe card; silicon substrate; Circuit testing; Copper; Etching; Fabrication; Integrated circuit interconnections; Integrated circuit testing; Micromechanical devices; Nickel; Probes; Silicon;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microprocesses and Nanotechnology Conference, 2003. Digest of Papers. 2003 International
  • Conference_Location
    Tokyo, Japan
  • Print_ISBN
    4-89114-040-2
  • Type

    conf

  • DOI
    10.1109/IMNC.2003.1268629
  • Filename
    1268629