Title :
Charge pump with Active Cycle regulation-closing the gap between linearand skip modes
Author :
Bayer, Erich ; Schmeller, Hans
Author_Institution :
Texas Instrum. Deutschland GmbH, Freising, Germany
Abstract :
Active Cycle regulation, a novel dual-loop regulation technique for charge pumps closes the gap between conventional “linear” and “skip” modes. It produces about the ripple of a “linear” controlled charge pump which is one order of magnitude less than the ripple of a “skip” mode converter. At the same time, it consumes just the quiescent current of a “skip” controlled charge pump, which is a few orders of magnitude less than that of a “linear” one. Thus it combines the best of the two worlds the authors have seen so far
Keywords :
DC-DC power convertors; power supplies to apparatus; switched capacitor networks; voltage multipliers; Active Cycle regulation; DC/DC power conversion; charge pumps; dual-loop regulation technique; linear mode convertor; quiescent current; ripple reduction; skip mode convertor; Availability; Batteries; Capacitors; Cellular phones; Charge pumps; Medical control systems; Microprocessors; Power generation; Space technology; Voltage control;
Conference_Titel :
Power Electronics Specialists Conference, 2000. PESC 00. 2000 IEEE 31st Annual
Conference_Location :
Galway
Print_ISBN :
0-7803-5692-6
DOI :
10.1109/PESC.2000.880528