Comparison of experimental techniques for determination of stray capacitances in high frequency transformers
Author
Lu, H.Y. ; Zhu, J.G. ; Ramsden, V.S.
Author_Institution
Fac. of Eng., Univ. of Technol., Broadway, NSW, Australia
Volume
3
fYear
2000
fDate
2000
Firstpage
1645
Abstract
A new approach for experimental determination of stray capacitances in high frequency transformers is proposed in this paper. This approach identifies the stray capacitances of a two winding transformer by conducting open and short circuit tests on both windings within the range of normal operation frequencies and fitting the π-shaped capacitor network model to the voltage and current readings. The experimental results of the stray capacitances in a 500 W two foil winding soft ferrite E-core high frequency transformer obtained by this two port network approach are compared with those obtained by the forced resonance and the step response approaches previously proposed by the authors. The merits and drawbacks of these approaches are also discussed
Keywords
capacitance; ferrite devices; high-frequency transformers; power transformer testing; step response; transformer cores; transformer windings; 25 kHz; 500 W; foil winding soft ferrite E-core; forced resonance; high frequency transformers; open circuit tests; short circuit tests; step response; stray capacitances determination; two port network approach; two-winding transformer; Capacitance; Capacitors; Circuit testing; Eddy currents; Frequency; Inductors; Magnetic cores; Magnetic resonance; Power electronics; Transformers;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics Specialists Conference, 2000. PESC 00. 2000 IEEE 31st Annual
Conference_Location
Galway
ISSN
0275-9306
Print_ISBN
0-7803-5692-6
Type
conf
DOI
10.1109/PESC.2000.880551
Filename
880551
Link To Document