DocumentCode
2582346
Title
A multimedia system for assessment of attachment organizations and heart rate
Author
Li, Zhan-Jian ; Soares, Isabel ; Silva, Maria Carolina ; Pinho, Armando ; Neves, Lúcia ; Costa, Ovidio ; Cunha, João Paulo Silva
Author_Institution
Dept. de Electron. e Telecoms, Aveiro Univ., Portugal
Volume
3
fYear
1998
fDate
29 Oct-1 Nov 1998
Firstpage
1226
Abstract
In this paper, we present a multimedia system named BioBeAMS (Bio-signal Behavior Attachment Multimedia System) for assessment of attachment organizations and heart rate in a strange situation experimental procedure for a mother to child attachment study (a well known psychological procedure). Attachment patterns assessed through this procedure have been conceived as different strategies to regulate the access to relevant attachment information and to process distress-related information. The psycho-physiological activation led by emotional processing of attachment experiences during the strange situation procedure may be a critical factor for understanding the subject´s psychological attachment strategies. BioBeAMS is an application which integrates bio-signals, video/audio of the psychological experimental procedure and the rater´s coding, running in the MS Window 95 environment on a PC. Using this system, we can acquire ECG signals and capture video and audio in a synchronous way. It also enables the raters to subsequently analyze and evaluate psychological and physiological events during review to study possible relations
Keywords
audio signal processing; electrocardiography; medical signal processing; microcomputer applications; multimedia computing; physiology; psychology; video signal processing; BioBeAMS; Biosignal Behavior Attachment Multimedia System; ECG signals; MS Window 95 environment; attachment organization assessment; audio; coding; distress-related information; emotional processing; heart rate assessment; mother to child attachment study; physiological events; psycho-physiological activation; psychological events; psychological procedure; strange situation experimental procedure; video; Area measurement; Biological processes; Electrocardiography; Heart rate; Multimedia systems; Pediatrics; Psychology; Skin; Telecommunications; Video equipment;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 1998. Proceedings of the 20th Annual International Conference of the IEEE
Conference_Location
Hong Kong
ISSN
1094-687X
Print_ISBN
0-7803-5164-9
Type
conf
DOI
10.1109/IEMBS.1998.747096
Filename
747096
Link To Document