• DocumentCode
    2582406
  • Title

    Testing of a high-efficiency domestic heating system

  • Author

    Rosa, L. ; Tosato, R.

  • Author_Institution
    Dept. of Mech. Eng., Padua Univ., Italy
  • fYear
    1989
  • fDate
    6-11 Aug 1989
  • Firstpage
    1749
  • Abstract
    An energy-loss model of gas-fired domestic boilers operating at partial loads and providing heating and tap water permits the calculation, using experimental parameters, of their cyclic efficiencies, including the effects of tank losses. These results agree with experimental values obtained by testing a prototype combined boiler characterized by a high nominal output (35 kW) and capable of maintaining high efficiency when it operates at loads required by heating installation (below 14 kW). This system gives high-efficiency values on both services
  • Keywords
    boilers; electric heating; space heating; testing; 14 kW; 35 kW; combined boiler; cyclic efficiencies; energy-loss model; gas-fired domestic boilers; heating installation; high-efficiency domestic heating system; partial loads; tank losses; tap water; testing; Automatic control; Boilers; Combustion; Heat transfer; Prototypes; System testing; Temperature control; Temperature dependence; Valves; Water heating;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Energy Conversion Engineering Conference, 1989. IECEC-89., Proceedings of the 24th Intersociety
  • Conference_Location
    Washington, DC
  • Type

    conf

  • DOI
    10.1109/IECEC.1989.74710
  • Filename
    74710