• DocumentCode
    2583469
  • Title

    50kVA Regenerative Active load for power test system

  • Author

    Ju-Won Baek ; Myung-Hyo Ryoo ; Jong Hyun Kim ; Jih-Sheng Lai

  • Author_Institution
    Korea Electrotechnol. Res. Inst., Changwon
  • fYear
    2007
  • fDate
    2-5 Sept. 2007
  • Firstpage
    1
  • Lastpage
    8
  • Abstract
    This paper presents 50 kVA active load with low loss, which regenerate the power to utility. To make the regenerative load, 3 phase back to back inverter using DSP320C33 have been made and tested. One inverter control the power flow of the test system and the other control the regeneration of the power to utility. It could be used as a nonlinear load, resistive load, and reactive load for single phase AC, DC, three phase AC. Also, load step change and unbalanced load is simply implemented by the proposed converter. The 50 kW prototype is made and tested to verify the regenerative load function.
  • Keywords
    high-voltage techniques; invertors; load regulation; voltage control; 3 phase back to back inverter; load step change; power test system; regenerative active load; unbalanced load; Circuit testing; Control systems; Electronic equipment testing; Load flow; Load flow control; Power supplies; Pulse width modulation; Pulse width modulation inverters; System testing; Voltage control; Active load; electronic load; grid-connection; regeneration;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Applications, 2007 European Conference on
  • Conference_Location
    Aalborg
  • Print_ISBN
    978-92-75815-10-8
  • Type

    conf

  • DOI
    10.1109/EPE.2007.4417523
  • Filename
    4417523