DocumentCode
2583469
Title
50kVA Regenerative Active load for power test system
Author
Ju-Won Baek ; Myung-Hyo Ryoo ; Jong Hyun Kim ; Jih-Sheng Lai
Author_Institution
Korea Electrotechnol. Res. Inst., Changwon
fYear
2007
fDate
2-5 Sept. 2007
Firstpage
1
Lastpage
8
Abstract
This paper presents 50 kVA active load with low loss, which regenerate the power to utility. To make the regenerative load, 3 phase back to back inverter using DSP320C33 have been made and tested. One inverter control the power flow of the test system and the other control the regeneration of the power to utility. It could be used as a nonlinear load, resistive load, and reactive load for single phase AC, DC, three phase AC. Also, load step change and unbalanced load is simply implemented by the proposed converter. The 50 kW prototype is made and tested to verify the regenerative load function.
Keywords
high-voltage techniques; invertors; load regulation; voltage control; 3 phase back to back inverter; load step change; power test system; regenerative active load; unbalanced load; Circuit testing; Control systems; Electronic equipment testing; Load flow; Load flow control; Power supplies; Pulse width modulation; Pulse width modulation inverters; System testing; Voltage control; Active load; electronic load; grid-connection; regeneration;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics and Applications, 2007 European Conference on
Conference_Location
Aalborg
Print_ISBN
978-92-75815-10-8
Type
conf
DOI
10.1109/EPE.2007.4417523
Filename
4417523
Link To Document