DocumentCode
2584907
Title
An investigation for combining optical and magnetic state selector in the cesium beam installation [Cs frequency standard]
Author
Bingying, Huang ; Shougang, Zhang ; Yunqing, Gan ; Changhua, Wu
Author_Institution
Nat. Inst. of Metrol., Beijing, China
fYear
1997
fDate
28-30 May 1997
Firstpage
245
Lastpage
248
Abstract
Describes an investigation into combining optical and magnetic state selector in the Cs beam installation. It was found that some characteristics in such a set-up are advantageous and attractive. The Ramsey resonance line-width observed is only about 1/3 of that obtained in general optical pumping case, and the mean velocity of signal atoms is slowed down to about 110 m/s
Keywords
atomic beams; caesium; frequency measurement; measurement standards; optical pumping; spectral line shift; 110 m/s; Cs; Cs beam installation; Cs frequency standard; Ramsey resonance line-width; cesium beam installation; magnetic state selector; mean velocity; optical and magnetic state selector; optical pumping; Atom lasers; Atom optics; Atomic beams; Fluorescence; Frequency; Laser beams; Laser excitation; Magnetic resonance; Magnets; Optical pumping;
fLanguage
English
Publisher
ieee
Conference_Titel
Frequency Control Symposium, 1997., Proceedings of the 1997 IEEE International
Conference_Location
Orlando, FL
Print_ISBN
0-7803-3728-X
Type
conf
DOI
10.1109/FREQ.1997.638552
Filename
638552