• DocumentCode
    2586240
  • Title

    High first torque harmonic due to insufficient function of dead time compensation in PWM inverters

  • Author

    Plotkin, Juriy ; Schaefer, Uwe ; Hanitsch, Rolf

  • Author_Institution
    Berlin Univ. of Technol., Berlin
  • fYear
    2007
  • fDate
    2-5 Sept. 2007
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    A new source for the DC current offset in the PWM inverter-fed loads is found. A significant irregularity in dead time voltage compensation due to a very small offset in phase current measurement is the cause for it. In the phase currents and voltages, high DC offsets appear at low current magnitudes, which lead to a first torque harmonic in the drive. Recommendations how to avoid this effect are given in the paper.
  • Keywords
    AC motor drives; PWM invertors; harmonics; machine control; torque; DC current offset; PWM inverters; dead time compensation; first torque harmonic; phase current measurement; voltage compensation; Automatic control; Automation; Current measurement; Delay; Magnetic field measurement; Pulse width modulation; Pulse width modulation inverters; Time measurement; Torque control; Voltage; Control of Drive; Converter control; Electrical Drive; Harmonics; Pulse Width Modulation (PWM);
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Applications, 2007 European Conference on
  • Conference_Location
    Aalborg
  • Print_ISBN
    978-92-75815-10-8
  • Electronic_ISBN
    978-92-75815-10-8
  • Type

    conf

  • DOI
    10.1109/EPE.2007.4417695
  • Filename
    4417695