• DocumentCode
    2593639
  • Title

    Comparison on the test results between reverberation chamber and anechoic chamber

  • Author

    Zhang Bo ; Yuan Zhiyong ; He Jinliang

  • Author_Institution
    Dept. of Electr. Eng., Tsinghua Univ., Beijing, China
  • fYear
    2012
  • fDate
    21-24 May 2012
  • Firstpage
    769
  • Lastpage
    772
  • Abstract
    Electromagnetic reverberation chamber has been widely used in EMC test. This paper compares the test results in reverberation chamber with those in anechoic chamber by using a simple PCB. The radiated immunity test results in the reverberation chamber are consistent with those in anechoic chamber. The problems of the radiated emission test in the reverberation chamber are analyzed. Feasibility of the substitution method for the total radiated power test in reverberation chamber is investigated by real test. It shows that the influence of the shape and the radiating direction of the EUT on the measured total-radiated power in reverberation chamber is very small. Thus, it is possible to substitute the EUT by standard antennas and the substitution method can be used to measure the total-radiated power in reverberation chamber.
  • Keywords
    anechoic chambers (electromagnetic); antenna testing; immunity testing; printed circuits; reverberation chambers; EMC test; EUT; PCB; anechoic chamber; electromagnetic reverberation chamber; radiated immunity test; radiated power measurement; standard antenna; substitution method; Antenna measurements; Antennas; Immunity testing; Q measurement; Standards; Systematics;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility (APEMC), 2012 Asia-Pacific Symposium on
  • Conference_Location
    Singapore
  • Print_ISBN
    978-1-4577-1557-0
  • Electronic_ISBN
    978-1-4577-1558-7
  • Type

    conf

  • DOI
    10.1109/APEMC.2012.6237860
  • Filename
    6237860