Abstract
The dissipation current waveform observation method is considered one of possible way as a diagnostic method for the un-bridged water tree on the high-voltage class power cable. In this paper, in order to clarify the time variations with the un-bridged water tree growth, by using the special chamber and setup, the dissipation current waveforms monitoring under the high voltage application test of LDPE sheet with soaking the sample into the saline solution was carried out at the applied frequency 1 kHz and applied voltage 2 kVrms for 300 hours. As the results of the high voltage application test, it was confirmed that the electric field dependence of the phase of 3rd harmonic of dissipation current strongly related with the deterioration rate of un-bridged water tree.
Keywords
electric current measurement; high-voltage engineering; insulation testing; polyethylene insulation; power cable insulation; power cable testing; trees (electrical); 3rd harmonic component monitoring; LDPE sheet; diagnostic method; dissipation current waveform monitoring; frequency 1 kHz; high-voltage class power cable; saline solution; time 300 h; unbridged water tree growth; voltage 2 kV; water tree deterioration rate testing; Atmospheric measurements; Cable insulation; Dielectrics and electrical insulation; Electrodes; Frequency; Monitoring; Power cables; Testing; Trees - insulation; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena, 2008. CEIDP 2008. Annual Report Conference on
Conference_Location
Quebec, QC
Print_ISBN
978-1-4244-2548-8
Electronic_ISBN
978-1-4244-2549-5
Type
conf
DOI
10.1109/CEIDP.2008.4772817
Filename
4772817
Link To Document