DocumentCode
2595016
Title
Nickel-Iron
Author
DeMar, Peter J.
Author_Institution
Battery Research and Testing, Inc., Oswego, NY, USA
fYear
2011
fDate
9-13 Oct. 2011
Firstpage
1
Lastpage
5
Abstract
This paper is going to look at real life aged 80+ year old Nickel-Iron cells that are still functional and will explain the simple recovery techniques that were documented in an original Edison Alkaline Storage Battery brochure from the 1920´s. Some of the cells had been charged intermittently, many had sat off charge for many years, and some had sat off charge and all but empty, but all made very substantial recoveries, and when subjected to discharge testing that followed the guidelines of the IEEE 1115 they all were able to pass load tests at their applicable rate.
fLanguage
English
Publisher
ieee
Conference_Titel
Telecommunications Energy Conference (INTELEC), 2011 IEEE 33rd International
Conference_Location
Amsterdam, Netherlands
ISSN
2158-5210
Print_ISBN
978-1-4577-1249-4
Electronic_ISBN
2158-5210
Type
conf
DOI
10.1109/INTLEC.2011.6099771
Filename
6099771