DocumentCode
2595406
Title
The experimental research of vortex flowmeter in vertical upward gas-liquid two-phase flow
Author
Hong-jun Sun ; Chao Huo ; Hua-Xiang Wang
Author_Institution
Coll. of Electr. Eng. & Autom., Tianjin Univ., Tianjin, China
fYear
2009
fDate
5-7 May 2009
Firstpage
167
Lastpage
170
Abstract
It is researched about the measurement characteristics of vortex flowmeter in air-water vertical upward two phase flow in this paper. The diameter of the pipeline is 50 mm, the flow velocities of the water vary from 0.849 m/s to 1.415 m/s and the void fraction of the gas is 1% to 20%. According to the experimental results, the repeatability of the vortex flowmeter can be used as a criterion for the stability of the flow. Meanwhile, the fitting formula is also given for the instrumental coefficient of vortex flowmeter through the analysis of the measurement error.
Keywords
flow measurement; flowmeters; measurement errors; pipe flow; two-phase flow; vortices; flow stability; flow velocities; gas void fraction; instrumental coefficient; measurement characteristics; measurement error; pipeline flow; size 50 mm; vertical upward gas-liquid two-phase flow; vortex flowmeter; Chemical industry; Fluid flow measurement; Gas industry; Instruments; Measurement standards; Pipelines; Testing; Valves; Velocity measurement; Water storage; instrument coefficient; two-phase flow; vortex flowmeter;
fLanguage
English
Publisher
ieee
Conference_Titel
Instrumentation and Measurement Technology Conference, 2009. I2MTC '09. IEEE
Conference_Location
Singapore
ISSN
1091-5281
Print_ISBN
978-1-4244-3352-0
Type
conf
DOI
10.1109/IMTC.2009.5168437
Filename
5168437
Link To Document