• DocumentCode
    2596378
  • Title

    Calibration of Rogowski coils at frequencies up to 10 kHz using digital sampling

  • Author

    Djokic, Branislav

  • Author_Institution
    Inst. for Nat. Meas. Stand., Nat. Res. Council of Canada, Ottawa, ON, Canada
  • fYear
    2009
  • fDate
    5-7 May 2009
  • Firstpage
    437
  • Lastpage
    441
  • Abstract
    A high-accuracy system for calibration of Rogowski coils at frequencies up to 10 kHz, based on a reference current transformer, an I/V converter, and a digital sampling system, is described in the paper. The calibration system has been automated and its performance evaluated. At the frequency of 10 kHz, the calibration system is capable of generating currents up to 100 A. At power frequencies, it is capable of generating currents up to 2,000 A. The best uncertainties (k=2) of the calibration system are estimated to be less than 500 μA/A for magnitude and 500 μrad for phase at 10 kHz, and an order of magnitude better at power frequencies.
  • Keywords
    calibration; coils; current transformers; power convertors; signal sampling; I/V converter; Rogowski coils; calibration; digital sampling; frequency 10 kHz; output signal digitization; power frequency; reference current transformer; Calibration; Coils; Current transformers; Digital-to-frequency converters; Frequency conversion; Frequency estimation; Phase estimation; Power generation; Sampling methods; Uncertainty; Rogowski coil; calibration; current transformer; digital sampling;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference, 2009. I2MTC '09. IEEE
  • Conference_Location
    Singapore
  • ISSN
    1091-5281
  • Print_ISBN
    978-1-4244-3352-0
  • Type

    conf

  • DOI
    10.1109/IMTC.2009.5168488
  • Filename
    5168488