DocumentCode :
2600222
Title :
Application of a combined capacitive flow velocity and density sensor for the measurement of liquid hydrogen mass flow
Author :
Holler, Gert ; Hrach, Daniel ; Fuchs, Adi ; Brasseur, Georg
Author_Institution :
Inst. of Electr. Meas. & Meas. Signal Process., Graz Univ. of Technol., Graz, Austria
fYear :
2009
fDate :
5-7 May 2009
Firstpage :
1444
Lastpage :
1448
Abstract :
The paper presents a capacitance-based measurement approach for measuring the flow velocity and the mean density of liquid hydrogen flows. The sensor allows for the measurement of liquid hydrogen flow velocity exploiting a spatial frequency based method for observing gaseous hydrogen bubbles moving through the sensing volume. Additionally, electrodes at both ends of the sensing section are used to determine the mean density of the cryogenic liquid (i.e. the liquid phase fraction inside the pipe). Measurement results for the flow velocity and the mass flow are presented.
Keywords :
bubbles; capacitive sensors; cryogenics; density measurement; flow sensors; hydrogen; velocity measurement; H2; capacitance-based measurement approach; cryogenic liquid; density sensor; flow velocity measurement; gaseous hydrogen bubble; liquid hydrogen mass flow; Capacitance measurement; Capacitive sensors; Density measurement; Fluid flow; Fluid flow measurement; Frequency measurement; Gas detectors; Hydrogen; Velocity measurement; Volume measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Instrumentation and Measurement Technology Conference, 2009. I2MTC '09. IEEE
Conference_Location :
Singapore
ISSN :
1091-5281
Print_ISBN :
978-1-4244-3352-0
Type :
conf
DOI :
10.1109/IMTC.2009.5168682
Filename :
5168682
Link To Document :
بازگشت