DocumentCode :
26006
Title :
A novel circuit for removing the entire current harmonic distortion generated by ohmic phase-cutting devices
Author :
Fathabadi, Hassan
Author_Institution :
Eng. Dept., Kharazmi Univ., Tehran, Iran
Volume :
6
Issue :
9
fYear :
2013
fDate :
Nov-13
Firstpage :
1786
Lastpage :
1791
Abstract :
In this study and for the first time, a novel harmonic remover circuit is presented that removes the entire current harmonic distortion generated by the phase-cutting devices, which have ohmic input impedance (ohmic phase-cutting devices) such as lighting dimmers. The presented circuit has been designed and an experimental prototype has been built in the laboratory. It has a very exact operation to remove the total harmonic distortion (THD). It really removes the entire harmonic and the THD% of the compensated device is equal to the THD% of the same device without any phase cutting, so if the THD% of the system without any phase cutting is zero then the THD% of the compensated device will also be zero. The real measurement and experimental results are presented to validate the theoretically results and make a comparison between the advantages of this work and other related works.
Keywords :
harmonic distortion; harmonics suppression; power supply circuits; THD; current harmonic distortion; harmonic remover circuit; lighting dimmers; ohmic input impedance; ohmic phase-cutting devices; total harmonic distortion;
fLanguage :
English
Journal_Title :
Power Electronics, IET
Publisher :
iet
ISSN :
1755-4535
Type :
jour
DOI :
10.1049/iet-pel.2012.0742
Filename :
6684260
Link To Document :