DocumentCode
2607292
Title
Pulse Evaluation of Integrated Circuit Metallization as an Alternative to SEM
Author
McAteer, O.J.
Author_Institution
Advisory Engineer, Westinghouse Electric Corporation, Advanced Technology Laboratories, Baltimore, Maryland 21203. 301-765-7259
fYear
1977
fDate
28216
Firstpage
217
Lastpage
224
Abstract
The present accepted industry-wide method of evaluating integrated circuit metallization is scanning electron microscope (SEM) inspection. This method, which has recently been incorporated into Mil-Std-883 (method 2018), is costly, time consuming, and subjective. A simple pulse technique that is inexpensive and objective has proven to be an effective alternative to the SEM method. Because of physical limitations of the pulse method in discerning certain reduced cross-sectional areas, limited usage of the pulse technique is recommended. This method, supplemented by the SEM, can result in significant cost savings.
Keywords
Costs; Inspection; Integrated circuit metallization; Integrated circuit technology; Laboratories; Metals industry; Microelectronics; Pulse circuits; Scanning electron microscopy; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Reliability Physics Symposium, 1977. 15th Annual
Conference_Location
LAs Vegas, NV, USA
ISSN
0735-0791
Type
conf
DOI
10.1109/IRPS.1977.362795
Filename
4208182
Link To Document