• DocumentCode
    2607292
  • Title

    Pulse Evaluation of Integrated Circuit Metallization as an Alternative to SEM

  • Author

    McAteer, O.J.

  • Author_Institution
    Advisory Engineer, Westinghouse Electric Corporation, Advanced Technology Laboratories, Baltimore, Maryland 21203. 301-765-7259
  • fYear
    1977
  • fDate
    28216
  • Firstpage
    217
  • Lastpage
    224
  • Abstract
    The present accepted industry-wide method of evaluating integrated circuit metallization is scanning electron microscope (SEM) inspection. This method, which has recently been incorporated into Mil-Std-883 (method 2018), is costly, time consuming, and subjective. A simple pulse technique that is inexpensive and objective has proven to be an effective alternative to the SEM method. Because of physical limitations of the pulse method in discerning certain reduced cross-sectional areas, limited usage of the pulse technique is recommended. This method, supplemented by the SEM, can result in significant cost savings.
  • Keywords
    Costs; Inspection; Integrated circuit metallization; Integrated circuit technology; Laboratories; Metals industry; Microelectronics; Pulse circuits; Scanning electron microscopy; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Reliability Physics Symposium, 1977. 15th Annual
  • Conference_Location
    LAs Vegas, NV, USA
  • ISSN
    0735-0791
  • Type

    conf

  • DOI
    10.1109/IRPS.1977.362795
  • Filename
    4208182