• DocumentCode
    2610363
  • Title

    Diagnostics in lamp research to evaluate HID-electrode and ballast performance

  • Author

    Adler, H.G.

  • Author_Institution
    OSRAM SYLVANIA Inc., Beverly, MA, USA
  • Volume
    5
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    3309
  • Abstract
    Electrodes in a high intensity discharge (HID) lamp play a major role in the successful operation of these light sources. On one hand a “good” electrode has to fulfil the fundamental task of supplying power to the discharge, on the other hand it has to survive the demanding conditions of the thermal and chemical environment in an HID lamp for many hours of operation. The performance of the electrodes during starting and continuous operation in an HID lamp is strongly dependent on the type of ballast used. Improper design of electrodes and ballasts can lead to life-limiting problems. The paper focuses on diagnostic efforts to shed some light on the complex electrode, plasma and ballast operation
  • Keywords
    discharge lamps; electrodes; lamp accessories; starting; HID lamp; HID-electrode performance; ballast performance; chemical environment; continuous operation; diagnostics; high intensity discharge lamp; light sources; plasma; starting; thermal environment; Anodes; Assembly; Cathodes; Electrodes; Electronic ballasts; Fault location; High intensity discharge lamps; Light sources; Power supplies; Tungsten;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industry Applications Conference, 2000. Conference Record of the 2000 IEEE
  • Conference_Location
    Rome
  • ISSN
    0197-2618
  • Print_ISBN
    0-7803-6401-5
  • Type

    conf

  • DOI
    10.1109/IAS.2000.882640
  • Filename