• DocumentCode
    2611218
  • Title

    Effectiveness of three alternative strategies in reducing the degrading impact of respiratory motion on the detection of small pulmonary nodules in SPECT imaging

  • Author

    Smyczynski, M.S. ; Gifford, H.C. ; Lehovich, A. ; McNamara, J.E. ; Segars, W.P. ; Dey, J. ; King, M.A.

  • Author_Institution
    Division of Nuclear Medicine, University of Massachusetts Medical School, Worcester, 01655 USA
  • fYear
    2008
  • fDate
    19-25 Oct. 2008
  • Firstpage
    3663
  • Lastpage
    3667
  • Abstract
    The objective of this investigation is to determine the effectiveness of three methods in reducing the impact of respiratory motion on the detection of small solitary pulmonary nodules in single photon emission computed tomographic imaging. Based on our previous work, 32 NCAT normal torso phantoms were generated over the entire respiratory cycle to create source and attenuation maps for the normal background distribution of Tc-99m NeoTect. Similarly, 32 NCAT sphere phantoms of 1.0 cm diameter were generated over the entire respiratory cycle for each of 150 uniquely located points within the lungs. The SIMIND Monte Carlo program was used to produce SPECT projection data for the normal background and separately for each of 150 lesions for all 32 frames and for a time-averaged case. Normal and tumor SPECT projection sets each containing one lesion were combined with a clinically realistic noise level and counts as follows: 1) end-expiration with all counts (frame 1), 2) time-averaged with all counts (frame av), and 3) each of the 32 frames containing 1/32 of the total counts. Projection data of the 32 frames was combined to form ten different bins. The first eight bins each consisted of 4 frames. The 9th bin, centered about end-expiration, consisted of 8 frames (quarter binning). The 10th bin, also centered about end-expiration, consisted of 16 frames (half binning). Each of the twelve sets of combined projection data was reconstructed with RBI-EM with RC. Based on known motion for each of the 150 different lesions, the reconstructed volumes of the first eight bins were shifted to superimpose the reconstructions over each of the 150 lesions. Comparison of lesion detection by human-observer LROC studies reveals that quarter binning results in the lowest rate of detection and that the reconstruct and shift method results in the greatest rate of detection. Additionally, the rate of detection by superimposing the reconstructions over the lesion is even superior to frame 1.
  • Keywords
    Attenuation; Degradation; Image reconstruction; Imaging phantoms; Lesions; Lungs; Motion detection; Optical computing; Single photon emission computed tomography; Torso;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2008. NSS '08. IEEE
  • Conference_Location
    Dresden, Germany
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-2714-7
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2008.4774111
  • Filename