  • Abstract
    The electrical system for the new RAI telecommunication station in Grottarossa (Rome) is a complex system that has to meet very high standards of performance. An approach to the design of such a system is proposed, based on reliability analysis applied to different scheme choices. Analysis results are compared with cost and other parameters of each solution, such as ease of maintenance and operation, flexibility, and availability, in order to find the one that best suits the telecommunication station requirements. The design approach was based on dividing the loads into three main categories, namely nonessential, essential, and uninterruptible loads, and selecting the appropriate solution for each category. The completed telecommunications station, now under construction, will comprise 10 buildings and cover 55000 m2
  • Keywords
    power supplies to apparatus; telecommunication systems; Grottarossa; LV power supply; RAI telecommunication station; Rome; availability; essential loads; flexibility; maintenance; nonessential loads; uninterruptible loads; Alternators; Character generation; Costs; Floors; Low voltage; Power cables; Power generation; Power systems; Uninterruptible power systems; Voltage transformers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Telecommunications Energy Conference, 1989. INTELEC '89. Conference Proceedings., Eleventh International
  • Conference_Location
    Florence
  • Type

    conf

  • DOI
    10.1109/INTLEC.1989.88277
  • Filename
    88277