DocumentCode
2613020
Title
Single op-amp proportional-integral compensator with antiwindup
Author
Kara, Miklos T. ; Rizkalla, Maher E.
Author_Institution
Dept. of Electr. Eng., Purdue Univ., Indianapolis, IN, USA
fYear
1993
fDate
3-6 May 1993
Firstpage
2260
Abstract
The authors describe an extremely simple, single op-amp proportional+integral compensator that has an inherent antiwindup function. During saturation, it not only stops and resumes the integrator but resets it according to the amount of overload, so under certain circumstances it has better overload handling. Originally, the circuit was developed as the output stage of a proportional-integral-derivative (PID)-type temperature controller
Keywords
active networks; compensation; integrating circuits; operational amplifiers; two-term control; antiwindup; integrator; output stage; overload; overload handling; proportional-integral compensator; saturation; Capacitors; Circuit simulation; Operational amplifiers; Process control; Resistors; Resumes; Switches; Temperature control; Voltage; Windup;