Title :
Comprehensive Model for Humidity Testing Correlation
Author_Institution :
3646 Highland St., Allentown, PA 18104. (215) 398-1222
Abstract :
This paper reviews all published life in humidity conditions vs life at 85C/85% RH for epoxy packages; 61 data points are used. An acceleration formula is described which provides direct extrapolation from test results in autoclave tests at up to at least 140C to low-humidity down to below 30XRH. This formula compares favorably with previously-published formulae. The possible effect of the Tg of the epoxy is recognized, and other high-temperature and low-humidity effects are disclosed. Recommendat ions are made for future tests, replacing 1000 hours at 85C/85%RH with a 20-hour test at 140C/100%RH, to reduce test time and increase test usefulness.
Keywords :
Extrapolation; Failure analysis; Humidity; Life estimation; Materials testing; Measurement standards; Packaging; Particle measurements; Stress measurement; Temperature;
Conference_Titel :
Reliability Physics Symposium, 1986. 24th Annual
Conference_Location :
Anaheim, CA, USA
DOI :