• DocumentCode
    2617516
  • Title

    Park integrated vector methods in motor fault diagnosis

  • Author

    Du, De

  • Author_Institution
    Sch. of Inf. & Control Eng., Weifang Univ., Weifang, China
  • fYear
    2011
  • fDate
    27-29 June 2011
  • Firstpage
    1470
  • Lastpage
    1473
  • Abstract
    This article studies Park vector method and the information fusion technology applies in the three-phase AC asynchronous motor breakdown synthesis diagnosis, to the electric motor movement´s voltage, the electric current, the electrical machinery temperature and the bearing vibration operating mode carries on the online monitor and the control, prompt, diagnoses the electric motor breakdown accurately and takes the corresponding measures, domestic was still for the first time.
  • Keywords
    electric breakdown; fault diagnosis; induction motors; machine bearings; vectors; vibrations; Park integrated vector method; bearing vibration operating mode; electric current; electric motor movement voltage; electrical machinery temperature; information fusion technology; motor fault diagnosis; online control; online monitor; three-phase AC asynchronous motor breakdown synthesis diagnosis; Artificial neural networks; Electric breakdown; Induction motors; Integrated circuits; Monitoring; Rotors; Windings; Information fusion; Synthesis diagnosis; Vector method;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computer Science and Service System (CSSS), 2011 International Conference on
  • Conference_Location
    Nanjing
  • Print_ISBN
    978-1-4244-9762-1
  • Type

    conf

  • DOI
    10.1109/CSSS.2011.5974520
  • Filename
    5974520