DocumentCode
2617950
Title
Fundamentals and Applications of Power Transfer Allocation Using Graph Theory in Systems with Loop Flow
Author
Zhao, Yue ; Irving, Malcolm R. ; Song, Yonghua
Author_Institution
Dept. of Electron. & Comput. Eng., Brunel Univ., Uxbridge
fYear
2005
fDate
2005
Firstpage
1
Lastpage
3
Abstract
In this paper, a novel elimination circulating flow method is suggested, an alternative reactive power pricing method in systems with circulating flow has been proposed, and a comparison between "bus-mixed average method" and "loop-breaking method" is displayed
Keywords
graph theory; power markets; power system economics; pricing; reactive power; bus-mixed average method; elimination circulating flow method; graph theory; loop flow; loop-breaking method; power transfer allocation; reactive power pricing method; Electricity supply industry; Graph theory; Load flow; Optimization methods; Power system security; Pricing; Production; Reactive power; Reactive power control; Voltage; Circulating Flow; Graph Theory; Loop Flow; Loop breaking;