DocumentCode
261829
Title
Semi-automatic localization of parathyroid tumors in dynamic sestamibi scintigrams
Author
Durovic, Marko ; Jankovic, Milica M. ; Markovic, Ana Koljevic
Author_Institution
Elektrotehnicki Fakultet, Univ. u Beogradu, Belgrade, Serbia
fYear
2014
fDate
25-27 Nov. 2014
Firstpage
955
Lastpage
958
Abstract
Parathyroid scintigraphy is considered to be an important method of preoperative imaging which enables localization of parathyroid tumors. Submarine method that uses images obtained by standard dynamic sestamibi scintigraphy has proved to be effective in case of typical pitfalls of existing scintigraphic methods. In this paper we described a developed Matlab interface that enables evaluation of algorithms for automatic application of Submarine method. We also suggested an algorithm for automatic extraction the whole thyroid region from the background radioactivity. Finally, we investigated the localization and visualization of parathyroid tumors based on estimation of exponential decreasing trend of time activity curves. The algorithm developed in Matlab environment was tested on a group of 20 patients with histologically proven parathyroid lesions.
Keywords
radioactivity; radioisotope imaging; tumours; Matlab interface; dynamic sestamibi scintigrams; parathyroid lesions; parathyroid scintigraphy; parathyroid tumor localization; parathyroid tumor visualization; preoperative imaging; radioactivity; scintigraphic methods; semiautomatic localization; submarine method; whole thyroid region; Computed tomography; Electronic mail; Heuristic algorithms; MATLAB; Single photon emission computed tomography; Tumors; Underwater vehicles;
fLanguage
English
Publisher
ieee
Conference_Titel
Telecommunications Forum Telfor (TELFOR), 2014 22nd
Conference_Location
Belgrade
Print_ISBN
978-1-4799-6190-0
Type
conf
DOI
10.1109/TELFOR.2014.7034564
Filename
7034564
Link To Document