DocumentCode
2621531
Title
Dose distributions in phantoms with different dimensions exposed to BNCT epithermal neutron beam: Measurements and calculations
Author
Bartesaghi, G. ; Burian, J. ; Carrara, M. ; Gambarini, G. ; Marek, M. ; Negri, A. ; Viererbl, L.
Author_Institution
INFN Sezione di Milano and with UniversitÃ\xa0 degli Studi, Dipartimento di Fisica, Milan, Italy
fYear
2008
fDate
19-25 Oct. 2008
Firstpage
1459
Lastpage
1461
Abstract
Boron neutron capture therapy (BNCT) is a cancer treatment still in development that is considered with increasing interest. It consists in irradiating with thermal or epithermal neutrons patients to whom a specific tumor-seeking Boron carrier has been administrated. The high cross section of the 10B(n, α)7Li reaction for thermal neutrons and the high radiobiological effectiveness are exploited in order to damage the tumour cells without afflicting the surrounding healthy tissues.
Keywords
Boron; Cancer; Imaging phantoms; Inductors; Medical treatment; Neutron capture therapy; Nuclear and plasma sciences; Particle beams; Performance evaluation; Tumors;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2008. NSS '08. IEEE
Conference_Location
Dresden, Germany
ISSN
1095-7863
Print_ISBN
978-1-4244-2714-7
Electronic_ISBN
1095-7863
Type
conf
DOI
10.1109/NSSMIC.2008.4774690
Filename
4774690
Link To Document